Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

887

14

Parameter reference

14.2

Parameter list | C02714

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C02714

C02715

C02716

C02717

Parameter | Name:

C02714 | Max. dist. manual jog [inc.]

Data type: UNSIGNED_32

Index: 21861

d

= 5565

h

Basic function "

Limiter

"

Display range

(min. value | unit | max. value)

0

Incr.

2147483647

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C02715 | Limitation active

Data type: UNSIGNED_32

Index: 21860

d

= 5564

h

Basic function "

Limiter

"

Selection list

(read only)

0 Deactivated
1 Activated

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C02716 | Resp. to limitation

Data type: UNSIGNED_32

Index: 21859

d

= 5563

h

Basic function "

Limiter

"

Selection list

1 Fault
2 Trouble
3 Quick stop by trouble
4 Warning locked
5 Warning
6 Information
0 No response

Subcodes

Lenze setting

Info

C02716/1

6: Information

Resp. to rotation limitation

C02716/2

3: Quick stop by trouble

Resp. to SW lim. pos. exceeded

C02716/3

6: Information

Resp. to max. value exceeded

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C02717 | LIM_dwControl

Data type: UNSIGNED_32

Index: 21858

d

= 5562

h

Bit coded control word of the basic function "

Limiter

".

Display range

(min. value | unit | max. value)

0

4294967295

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1