Parameter reference

14.2

Parameter list | C02781

894

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C02781

C02785

C02786

C02787

Parameter | Name:

C02781 | ManualJogOpenLoop: Dig. signals

Data type: UNSIGNED_32

Index: 21794

d

= 5522

h

From software version V7.0

Display of the digital signals of the basic function "

Manual jog open loop

".

Selection list

(read only)

0 FALSE
1 TRUE

Subcodes

Info

C02781/1

MOL_bEnable

C02781/2

MOL_bJogPositive

C02781/3

MOL_bJogNegative

C02781/4

MOL_bSelectTab1

C02781/5

MOL_bSelectTab2

C02781/6

MOL_bEnabled

C02781/7

MOL_bActive

C02781/8

MOL_bDone

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C02785 | PPI activation

Data type: UNSIGNED_32

Index: 21790

d

= 551E

h

From software version V7.0

Basic function "

pole position identification

"

Selection list

(Lenze setting printed in bold)

0 PPI disabled
1 PPI active

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C02786 | PPI mode

Data type: UNSIGNED_32

Index: 21789

d

= 551D

h

From software version V7.0

Basic function "

pole position identification

"

Selection list

(Lenze setting printed in bold)

0 360°
1 <20°

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C02787 | PPI_dnState

Data type: INTEGER_32

Index: 21788

d

= 551C

h

From software version V7.0

Status of the basic function "

pole position identification

".

Display range

(min. value | unit | max. value)

-2147483648

2147483647

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1