5 manual job, encoderless, Manual job, encoderless, Manual job, encoderless ( 407) – Lenze 9400 User Manual

Page 407: 11 basic drive functions

Advertising
background image

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

407

11

Basic drive functions

11.5

Manual job, encoderless

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

11.5

Manual job, encoderless

This function extension is available from software version V7.0!

The basic function "Manual jog (OL)", which is implemented in the motor control system of the drive

controller, enables the user to operate the drive without control (i.e. "open loop", encoderless) and

independently of the selected operating mode:

• If the motor is asynchronous, the speed depends on the load.
• A synchronous motor turns with a prescribed field frequency.

The basic function "Manual jog (OL)"

• is based on the I-rotation test mode and is especially suitable for the operation of synchronous

motors. There is a corresponding dialog box in »Engineer«

• is not identical with sensorless operation of synchronous machines. In the basic function

"Manual jog (OL)", neither parameters relevant to the motor model nor parameters relevant to

the motor type are used

• can be activated and controlled by means of process data (system block inputs) or by accessing

codes (e.g. via keypad).

Uses of "Manual job, encoderless"

• Test of hardware (e.g. connection system, rotating field and motor cables) during initial

commissioning and during servicing

• Movement of the drive or machine to a service position in the event of defective encoder

feedback

• Functional test of the discretely structured feedback system of a torque or linear motor.

Danger!

In this basic function, the extent of the useable operating modes of the holding brake is

restricted. Only the following operating modes function:

• Directly with brake module (

C02580, selection 1

) and

• Direct switching externally (

C02580, selection 11

)

Stop!

It is only permissible to activate controlled operation of synchronous machines if the

following parameters have been set correctly, in addition to correct assignment of the

encoder image and the motor's rotating field:

• Motor control SC, "Servo control of sync motor" (

C00006, selection 1

)

• Pole position of the motor encoder (

C00058

)

• Motor data (

C00081

...

C00091

)

• Active resolver feedback or encoder feedback as motor encoder (

C00420

...

C00422

)

Advertising
This manual is related to the following products: