Parameter reference

14.2

Parameter list | C02870

904

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C02870

C02871

C02900

C02901

Parameter | Name:

C02870 | Service code

Data type: UNSIGNED_32

Index: 21705

d

= 54C9

h

This code is for device-internal use only and must not be written to by the user!

Parameter | Name:

C02871 | Voltage reserve

Data type: UNSIGNED_32

Index: 21704

d

= 54C8

h

From software version V12.0

Voltage reserve at the transition point to field weakening

• Only relevant for servo control for asynchronous motor (selection "2" in

C00006

).

Setting range

(min. value | unit | max. value)

Lenze setting

1

%

20 5 %

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C02900 | User Password

Data type: VISIBLE_STRING

Index: 21675

d

= 54AB

h

From software version V3.0

If the cam data are provided with a user password, the defined user password must be entered once to execute the

following actions:

• Changing the cam data via parameter setting

• Loading/saving the cam data

Validity

The user password entered is maintained until the next download, mains switching, or until reset by the user

(logout).

• You can "logout" deliberately by entering an invalid password.

Basic function "

Cam data management

"

Read access  Write access  CINH  PLC STOP  No transfer

Character length: 22

Parameter | Name:

C02901 | CamMemory

Data type: UNSIGNED_32

Index: 21674

d

= 54AA

h

From software version V5.0

Basic function "Cam data management":

Memory mapping

Display range

(min. value | unit | max. value)

0

4294967295

Subcodes

Info

C02901/1

Size of the memory for quick download to RAM

C02901/2

Size of the memory for "Online change"

C02901/3

Size of the memory from which the cam data are

processed.

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1