Hyundai HI4 User Manual

Page 145

Advertising
background image

3. Service menu

━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━

----------------------------------------------------------------------------------------

3 - 76

3.7.4 Error logging

Outline

It displays the occurred error until now. It makes the restoration work, the occurring

cause of error judge correctly by referring to the history of error until now.

Screen display

Operation Method

Following is displayed as selecting 1: W0005 25 10:27.

When you select either of followings, General Input/Output, Axis data, Fixed

Input/Output, state condition of each signals or data at the error occurrence.

14:39:38 *** Error logging *** A:0 S:4

1: W-0005 25 10:27

2: E-0107 25 10:27
3: E-0107 25 10:27
4: E-0008 25 10:26
5: E-0008 24 12:44
6: E-0120 24 10:44
7: E-0008 24 19:23
8: E-0107 23 18:28
9: E-0190 23 15:36
10: E-0190 23 12:29
11: E-0008 22 10:44

Use [Number]/[Up][Down] and press [SET].

>

Refresh?

Previous

Next

14:39:38 *** Error Log NO. 01*** A:0 S:4

W0005 Backup battery voltage drop.
2001-07-25 10:27:11
Program No. =000 Step No. =000
** Selection **
[

I signal

] [O signal] [Axis data]

[Fixed Input] [Fixed output]

Use [Up][Down] and press [SET].

>

Advertising