Hyundai HI4 User Manual

Page 187

Advertising
background image

6. System setting

------------------------------------------------------------------------------------------------

----------------------------------------------------------------------------------------

6 - 23

6.2.1.8 Setting the Earlier output

Outline

Usually, the DO signal output after getting to the step, You can use this function

when you output DO signal before getting to the step by setting this function.

Screen display

Screen description

„ Earlier out time : It sets the first out time of group output signal( GO) or each

output signal before getting to the step.

„ DO lower number : This is a first number of each output signal(DO) that is going to

do first out.

„ DO upper number : This is a last number of each output signal(DO) that is going

to do first out.

„ GO lower number : This is a first number of each output signal(GO) that is going

to do first out.

„ GO upper number : This is a last number of each output signal(GO) that is going

to do first out.

Reference

„ But, This first out function can't apply when the step go and back in manual

mode.

„ If you press “ Complete” [PF5] key, save the changed information. If press [CANCEL]

key , Cancel them.

14:39:38 *** Earlier output *** A:0 S:4

Sig Time Low DO High DO
DO = [

0.00

]sec [ 0] [ 0]


Low GO High GO
O-bype= [ 0.00]sec [ 0] [ 0]


Select and Enter number. Press [SET]

>[1 - 99.9]

Advertising