1 conveyor operation – Hyundai HI4 User Manual

Page 160

Advertising
background image

5. Application condition

------------------------------------------------------------------------------------------------

----------------------------------------------------------------------------------------

5 - 3

5.1 Conveyor operation

Outline

It determines the movement of robot when robot handles workpiece on conveyor,

① Normal : Robot moves synchronously according to actual movement of workpiece on

conveyor.

② Simulation : Without operating conveyor, user can operated robot movement by

entering conveyor speed. It is useful to check cycle time after teaching.

③ Test : Like plat test, it is the condition where conveyor is not operated and robot

movement can be checked. Different aspects from plan test is that teaching

point can be checked at stop condition of workpiece as pulse count is not

reset even though executing Program END

Reference

„ Depending on setting condition for conveyor movement, the following is displayed

in manual or auto mode.

„ Conveyor pulse count not to related move type is only counted by activation of limit

switch.

„ In simulation, value calculated from distant is not always correct because pulse

counter of conveyor is separated from registry

„ Normally, in playback mode, conveyor speed has actual movement speed of conveyor,

but, in plan test operation, plan test speed entered from user is always 0 value.

14:39:38 *** A U T O *** A:0 S:4

T0

C-N SR:100% 1Cycl

PN:100[*]__ S/F:4/0

Robot:H120, 6axes, 10 steps

S1 MOVE P,S=100%,A=0,T=1
S2 MOVE P,S=100%,A=0,T=1
S3 MOVE P,S=100%,A=0,T=1
S4 MOVE P,S=100%,A=0,T=1
S5 MOVE P,S=100%,A=0,T=1
S6 MOVE P,S=100%,A=0,T=1
S7 MOVE P,S=100%,A=0,T=1
S8 END


>

Service

Rel WAIT

Cond Set

According to the
Mode,“C-N","C-S","
C-T" are displayed.

Advertising