Hyundai HI4 User Manual

Page 379

Advertising
background image

11. Robot Language Explanation

------------------------------------------------------------------------------------------------

----------------------------------------------------------------------------------------

11 - 14

11.2.3 I/O

11.2.3.1 I/O Substitution

11.2.3.2 PRINT Command

Description Outputs DO signal or inputs the DI signal status.

Syntax

<Output Variable> = <Output Value>
<Arithmetic Variable> = <Variable>

Output
Variabl

Variable corresponding to DO signal.
Single signal is DO, Group signal is GO

Output
Value

Arithmetic Equation. 0∼255. (Discards the digits after the decimal
point if float type)

Parameter

Input
Variabl

Variable corresponding to DI signal.
Single signal is DI, Group signal is GI

example

DO3 = 1 GO2 = &H7F
V20% = DI2 V21% = GI2

Description Outputs the specified information to Teach Pendant screen or to serial port.

Syntax

PRINT <Output Direction>, <Information,… >

Output
Directi
on

#0 : Teach Pendant
#1 : Serial port COM 1
#2 : Serial port COM 2

Parameter

Informa
tion

Arithmetic Equation., String equation

example

PRINT #0, "SIGNAL VALUE = " ; V1!

Comment

If the information is divided by ',', informations are separated by 1 character
space’ and by ‘ ;’ , it is output without space.
If ‘ ;’ is at the end, no open line character is attached.