8 (8) r44 conveyor data clear – Hyundai HI4 User Manual

Page 289

Advertising
background image

7. R code

------------------------------------------------------------------------------------------------

----------------------------------------------------------------------------------------

7 - 13

7.8 (8) R44 CONVEYOR DATA CLEAR

Outline

It clears Conveyor data ; CP, CR, CS.

The content which will be cleared can be different according to the selected mode at "Cond

Set"[PF5] -> "Applicnd"[PF1] -> 1: Conveyor oper = <Normal, Simulat, Test> as table.

It is the same function with 2.Conveyor data reset of "Service"[PF1] -> 2.Register ->

6. Conveyor Data.

Screen display

„ If you select [YES], the conveyor data shall be cleared.

Otherwise, If you select [NO], this function shall be cancelled.

Reference

⑴ It cannot be executed during operation.

⑵ The limit switch input state will be cleared, too. So, to start pulse counting, it

needs new limit switch input.

General

Simulation

Test

CP(Pulse)

CLEAR

Keep present

pulse

CLEAR

CR(Distance)

CLEAR

CLEAR

CLEAR

CS(Speed)

CLEAR

CLEAR

Always '0'

Conveyor data clear. Continue? [YES/NO]

>