6. System setting

------------------------------------------------------------------------------------------------

----------------------------------------------------------------------------------------

6 - 69

6.4.1.1 Welding parameter


Outline


It makes the welding work possible efficiently to save the information that is

necessary when it welds is a spot welding or stud welding.


Screen display

Contents of the screen


„ Gun wait time (sec.) : It is a time when waits till the robot stops completely

before outputting the gun signal.


„ Robot wait time (sec.) : It is a time when waits till the gun is opened completely

after inputting the gun signal output and welding end signal. That is to say, it

is a time when waits till the time the robot's movement starts after pressurizing

the gun.


„ Brake wait time (sec) : It is a wait time to prevent the welding inferiority by

calibrating the ON/OFF motion completion time of motor brake. It holds the

motor brake because of the repulsion in the stud welding. It is a time when waits

till the motor brake operates completely.


„ Weld stick detection (sec.) : It is a option.

14:39:38 *Air-gun welding data* A:0 S:4

[Welding parameter] = [ GUN1] [ GUN2]
GUN waiting time(sec) = [

0.00

] [ 0.00]

Robot WAITg time(sec) = [ 0.00] [ 0.00]
Brake WAITg time(sec) = [ 0.00] [ 0.00]
Sticking detect (sec) = [ 0.00] [ 0.00]
Rewelding count = [ 0] [ 0]
Reweld wait time(sec) = [ 0.00] [ 0.00]
Slip detect range(mm) = [ 0] [ 0]
Slip detect count = [ 0] [ 0]
Pulse width(0=level) = [ 0.00] [ 0.00]
Earlier gun time(sec) = [ 0.00] [ 0.00]
----------------------------------------
[Welding parameter]
Weld Cond Synchro = <

Disable

,Enable>

Weld Cond out type = <

Discrete

,Binary>

Earlier Cond time = [ 0.00]
WI common use = <

Disable

,Enable>



Select and Enter number. Press [SET]

>[0.00 - 1.00]