9. Quick Open Function

------------------------------------------------------------------------------------------------

----------------------------------------------------------------------------------------

9 - 19

9.10.2 welding sequence

If you select welding sequence, following screen is displayed. The detail about screen

can be referred to “ system” [PF2] → 4: application parameter → 1: spot & stud →

3: spot welding data (condition, sequence) → 2: welding system part. The difference

from this part is that the number of welding sequence can not be changed but only the

parameter about relevant welding sequence number can be changed.

14:39:38 *** Weld Sequence *** A:0 S:4

Welding Sequence 1
Condition signal =< DSBL,

ENBL

>

Squeeze signal =<

DSBL

,ENBL >

Welding command signal=< DSBL,

ENBL

>

WI wait =< DSBL,

ENBL

>

Welding wait time =[0.00]
Welding end wait time =[0.00]

Press [SHIFT]+[<-][->] Key.

>