6. System setting

------------------------------------------------------------------------------------------------

----------------------------------------------------------------------------------------

6 - 77

6.4.1.3.1 Common data

Outline

It is a data which is applied in commonness without having concern with the welding

condition or sequence number.

Screen display

Contents of the screen

„ Treatment in the error : It is a treatment when the welding completion signal isn't

inputted.

① Interlock wait : It wait until the welding completion signal is inputted.

② Stop : If the welding completion signal isn't inputted, it makes the robot

stopped by treating as an error.

„ Gun open in the error/stop : It opens the servo gun and stops when the error or

stop occurs under the welding.

„ WI common use : It is a data that decides whether the welding completion signal

uses in commonness or not in case of using the servo gun more than two.

① Disable : It doesn't use the welding completion signal in commonness.

② Enable : It use the welding completion signal in commonness.

14:39:38 *** Common Data *** A:0 S:4

Error processing =< Interlock,

Stop

>

GUN open to error stop =< DSBL,

ENBL

>

WI common use =<

DSBL

,ENBL >





Press [SHIFT]+[<-][->] Key.

>