Hyundai HI4 User Manual

Page 392

Advertising
background image

11. Robot Language Explanation

------------------------------------------------------------------------------------------------

----------------------------------------------------------------------------------------

11 - 27

11.3.3 SPOTCND Command

Introduction

Spot welding condition signal is used to change the welding current according the

thickness of the materials or sheets when spot welding.

Welding condition can be freely changed by connecting this signal to the welder. The

welding condition can be to maximum 256 level (0 ∼ 255) .

It is output in Binary type of 8bit (0 ∼ 255) .

Or it can be output in Discrete type (0 ∼ 7) when selecting <Line No> of welding

condition output type (SYSTEM[PF5] → 4.APPLICATION PARAMETER → 1.SPOT&STUD → 1.

WELDING PARAMETER)

This signal is to output as welding condition number that is fixed up in "SYSTEM [PF5]

→ 2. CONTROL PARAMETER → 1. SET UP IN/OUT SIGNAL → 6. ARRAY OUTPUT SIGNAL.

11.3.4 SREQ Command

Introduction

SREQ is a function to request external equipment to send shift amount. The shift

amount is recorded in on line shift register group.

When this function is executed, robot would output data of the format such as SHIFT

※1 CR LF (※1 is register No.) through RS232C port. Then, robot would receive data

of the format such as SHIFT X, Y, Z, θ X, θ Y, θ Z, CR. The input is recorded in the

register ※1. The format of transmit data is ASCII code.

Description Spot Welding Condition (M33)

Syntax

SPOTCND <Condition Number>

Parameter

Condition
Number

The condition number output to the welder for welding
current change.

0∼255

example

SPOTCND 2

Description Shift Requirement (M51)

Syntax

SREQ R=<Register Number>,PT=<Port Number>

Reg. Number Register number for saving the received shift amount. 1∼8

Parameter

Port Number

RS232C port number to be used for shift requirement and
transmission.

1∼1

example

SREQ R=1,PT=1