6. System setting

------------------------------------------------------------------------------------------------

----------------------------------------------------------------------------------------

6

- 68

6.4.1 Spot & Stud

Outline

It is set to perform the spot & stud welding work.

Screen display

Reference

„ The welding parameter is taken in custody in the control constant file (ROBOT.C00)

and the servo gun parameter and the equalizing parameter are taken in custody in

the machine constant file (ROBOT.C01).

„ The spot welding data is taken in custody in the spot welding condition file (ROBOT.

WSD).

„ In case that the control constant file, the machine constant file and the spot welding

condition file are protected completely, it can't be changed.

14:39:38 *** Spot&Stud Weld *** A:0 S:4

1: Air-gun welding data

2: Servo gun parameter
3: Servo-gun welding data(Cnd,Seq)
4: Air-gun equalizing parameter



Use [Number]/[Up][Down] and press [SET].

>