9. Quick Open Function

------------------------------------------------------------------------------------------------

----------------------------------------------------------------------------------------

9 - 14

9.7 WELDING AUXILIARY CONDITION - AUTO. WIRE STICK RELEASE

Outline

If you select “ auxiliary condition” [PF1] at welding end condition, automatic wire

stick release setting screen is displayed as followings.

Entry screen

Screen contents

„ Number of times : It inputs the maximum repeating times of wire stick release.

„ Current : It inputs the output value of welding current during a wire stick release.

„ Voltage : It inputs the output value of welding current during processing a wire stick

release.

„ Delay time : It inputs the time when a wire stick release condition outputs.

Reference

„ Move a cursor on the content which you want to change, and press [SET] and inputting

numerical number. The setting value will be changed. You should press "completion"[PF5]

to save the changed value.

14:39:38** Arc Condition File **A:0 S:4

ARC AUXILIARY CONDITION FILE
<AUTO STICK RECOVERY>
Repeat : [1] Times
Current : [ 0] A
Voltage : [

20.0

] V

Delay : [0.30] sec

Select and Enter number. Press [SET]

>[0.0 - 200.0]