5 gun search reference point record – Hyundai HI4 User Manual

Page 163

Advertising
background image

5. Application condition

------------------------------------------------------------------------------------------------

----------------------------------------------------------------------------------------

5

- 6

5.5 Gun Search reference point record

Outline

In case of using servo gun or equalizer, reference position shall be recorded to reduce

wear of electrode.

Refer to Servo gun manual or robot equalizer manual for Gun search operation

① Off : Disable function of Gun search reference position record

② On : Enable function of Gun search reference position record

Reference

„ The following is displayed in Manual or Auto mode, as setting On for Gun search

reference position record

„ After installation of system, replace electrode with new and operate one cycle before

teaching job.

„ “ System” [PF2] → 3. Machine parameter → 5. Setting encoder offset 2. Encoder

calibration (Data input) must be set and 1 cycle of playback has to be performed

to record Gun Search reference point

„ Without recording Gun search reference point, error will occur if spot welding or

Gun Search is executed,

14:39:38 *** A U T O *** A:0 S:4

T0 G1 SW

Wd-On

SR:100% 1Cycl

PN:100[*]__ S/F:4/0 W:01S:01

Robot:H120, 6 axes, 10 steps

S1 MOVE P,S=100%,A=0,T=1
S2 MOVE P,S=100%,A=0,T=1
S3 MOVE P,S=100%,A=0,T=1
S4 MOVE P,S=100%,A=0,T=1
S5 MOVE P,S=100%,A=0,T=1
S6 MOVE P,S=100%,A=0,T=1
S7 MOVE P,S=100%,A=0,T=1
S8 END


>

Service

Rel WAIT

Cond Set

State of (Gun) search
reference position record.

Advertising