6. System setting

------------------------------------------------------------------------------------------------

----------------------------------------------------------------------------------------

6 - 79

6.4.1.3.3 Welding sequence

Outline

It is a data that decides the welding sequence of controller in the playback of

the spot welding.

Screen display

Contents of the screen

„ Number : It is the number that designates in the spot welding function and there

are 64 unit.

„ Condition signal : It designates whether to output the welding condition signal

or not. Currently, this item is fixed to <Enable>.

„ Pressurization signal : It designates whether to output the pressurization signal

or not. Currently, this item is fixed to <Disable>.

„ Weld signal : It designates whether to output the weld signal or not. Currently,

this item is fixed to <Enable>.

„ WI wait : It designates whether to do the welding completion wait or not after

outputting the weld signal. Currently, this item is fixed to <Enable>.

„ Weld wait time : It designates the wait time of welding completion signal after

outputting the weld signal. The 0.0 is the infinite wait.

„ Welding completion wait time : It designates the wait time of until the gun opens

after completing the welding. But in case that the gun open time is short, the

14:39:38 *** Weld Sequence *** A:0 S:4

Number =[

1

]

Condition signal =< DSBL,

ENBL

>

Squeeze signal =<

DSBL

,ENBL >

Welding command signal =< DSBL,

ENBL

>

WI wait =< DSBL,

ENBL

>

Welding wait time =[0.00]
Welding end wait time =[0.00]

Select and Enter number. Press [SET]

>[1 - 64]