2 set port mirroring, Set port mirroring -44, Section 4.3.9.2 – Enterasys Networks 1G58x-09 User Manual

Page 190

Advertising
background image

Port Configuration Command Set

Setting Port Mirroring

4-44

Matrix E1 Series (1G58x-09 and 1H582-xx) Configuration Guide

Ethernet front panel port 4, and Fast Ethernet front panel port 23 is mirroring traffic from Fast
Ethernet front panel port 19. Mirroring is currently disabled on the device:

4.3.9.2

set port mirroring

Use this command to enable, disable or configure mirroring between ports.

set port mirroring {disable | enable | source_port target_port}

Syntax Description

Command Defaults

None.

Command Type

Switch command.

Matrix>show port mirroring

Port Mirroring Status : Disabled

===============================

Source Port = fe.0.4

Target Port = fe.0.11

===============================

Source Port = fe.0.19

Target Port = fe.0.23

disable | enable

Disables or enables port mirroring.

source_port

Specifies the port designation for the source on which the
traffic will be monitored. For a detailed description of
possible port-string values, refer to

Section 4.1.2

.

target_port

Specifies the port designation for the target that will
duplicate or “mirror” all the traffic on the monitored port.
For a detailed description of possible port-string values,
refer to

Section 4.1.2

.

NOTES: A given source port may only be mirrored to one target port. However, multiple
source ports may be mirrored to the same target port.

Only one port per port grouping can be designated as a source port. For more
information on port grouping designations, refer to

Section 4.3.10.2

.

A maximum of 12 source/target port pairs may be configured.

Advertising
This manual is related to the following products: