37 set spantree txholdcount, Set spantree txholdcount -33, Section 6.2.1.37 – Enterasys Networks 1G58x-09 User Manual

Page 319

Advertising
background image

Spanning Tree Configuration Command Set

Reviewing and Setting Spanning Tree Bridge Parameters

Matrix E1 Series (1G58x-09 and 1H582-xx) Configuration Guide

6-33

Command Type

Switch command.

Command Mode

Read-Only.

Example

This example shows how to display the transmit hold count setting:

6.2.1.37 set spantree txholdcount

Use this command to set the maximum BPDU transmission rate. This is the number of BPDUs
which will be transmitted before transmissions are subject to a one-second timer.

set spantree txholdcount txholdcount

Syntax Description

Command Defaults

None.

Command Type

Switch command.

Command Mode

Read-Write.

Example

This example shows how to set the transmit hold count to 5:

Matrix>show spantree txholdcount

Tx hold count = 3.

txholdcount

Specifies the maximum number of BPDUs to be
transmitted before transmissions are subject to a
one-second timer. Valid values are 1 to 10. Default
value is 3.

Matrix>set spantree txholdcount 5

Advertising
This manual is related to the following products: