Valid values for vlan classification, Valid values for vlan frame filtering, Table 7-1 – Enterasys Networks 1G58x-09 User Manual
Page 371: Table 7-2, To c, Provides the

VLAN Configuration Command Set
Assigning VLANs According to Classification Rules
Matrix E1 Series (1G58x-09 and 1H582-xx) Configuration Guide
7-29
Table 7-1
Valid Values for VLAN Classification
data_meaning keywords
data_value keywords
(value applied)
data_ mask
Ethernet-II-Type
•
05F6 - FFFF (valid range)
•
AppleTalk (809B)
•
Banyan-Vines (0BAD)
•
DECNET (6003)
•
IP (0800 and 0806)
•
IPX (8137)
•
RARP (8035)
Not applicable.
NOTES: The Matrix E1 allows the use of 3 user defined Ethernet II Type values for
classification into a VLAN. AppleTalk, Banyan-Vines and RARP are considered user
defined, but are listed as options. Additional user defined Ethernet II Type values will
filter (drop) untagged frames as described in
. IP and DECNET rules also
classify the SNAP frame type.
802.3-SAP
•
IPX-LLC (E0E0)
•
IPX-RAW (FFFF)
•
IPX-SNAP (AAAA)
•
Netbios (F0F0)
•
SNA (0000, 0404, 0808
and 0C0C)
Not applicable.
Table 7-2
Valid Values for VLAN Frame Filtering
NOTE: The parameters in this table DO NOT classify frames into a specific VLAN,
Untagged frames received with any of the data_meanings listed below will be dropped
and not forwarded.
data_meaning
data_value(s)
data_ mask
IP-TOS (Type of Service)
Integer (0 - 255)
Not applicable