Logging and Network Management Command Set

Configuring System Logging

11-16

Matrix E1 Series (1G58x-09 and 1H582-xx) Configuration Guide

11.2.1.12set logging application

Use this command to set the severity level of log messages for an application.

set logging application {mnemonic | all} level

Table 11-2

show logging application Output Details

Output

What It Displays...

Application

Mnemonic values for applications being logged. For details
on setting this value using the set logging application
command, refer to

Section 11.2.1.12

. For a list of valid values

and their corresponding applications, refer to

Table 11-3

.

Current Severity
Level

Severity level (from 1 to 8) at which the server is logging
messages for the listed application.

NOTE: Most system messages are logged at
severity level of 6 (Notice). By default, the logging
applications are set to 5 (Warning),

which will

suppress level 6 (Notice) messages from the
console session. To view most of the logging of
configuration messages on the console session,
ACL hits etc, the set logging application
command should be used as described in

Section 11.2.1.12

to set the logging level for

applications to 6 or higher.