4

Drive interface

4.3

Device states

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

4.3.4

"Device is switched on" state

The drive is in this device status if the DC bus voltage is applied and the controller is still inhibited

by the user (controller inhibit).

• The bus systems are running and the terminals and encoders are evaluated.
• The monitoring functions are active.
• The controller can be parameterised and device commands can be executed to a limited extent.
• The functions of the user task can be used.

• Precondition: The application has started (status display in

C02108

).

• The basic drive functions cannot be used yet.
• If the controller is enabled, the motor builds up a torque.

4.3.5

"Operation" state

In this device state the motor follows its setpoint according to the basic drive function selected.

Danger!

If automatic restart is enabled (

C00142

= "1: Enabled"), the drive can restart

automatically from the "Trouble" and "Safe torque off" device states when the trouble or

request for "Safe torque off active" has been eliminated!

Automatic restart after mains connection/trouble...

( 104)

LED DRIVE READY

LED DRIVE ERROR

Display in

C00183

OFF

90: Drive is switched on

LED DRIVE READY

LED DRIVE ERROR

Display in

C00183

OFF

0: Operation