4 dc bus overvoltage, Dc bus overvoltage, Dc bus – Lenze 9400 User Manual

Page 272: Overvoltage, 7braking operation

Advertising
background image

7

Braking operation

7.2

Monitoring

272

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

7.2.4

DC bus overvoltage

If, due to a too high braking energy, the DC-bus voltage exceeds the overvoltage threshold which

results from the mains voltage setting in

C00173

, the "Overvoltage in the DC bus" error message is

output and the response set in

C00600

is activated (default setting: "Trouble").

Note!

For hoist applications, the "Fault" response should be selected in

C00600

(in combination

with an emergency stop via mechanical brakes).