I/O terminals

8.6

"State bus" monitoring function

284

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

8.6.1

Detecting the current state

Via the output DIGIN_bStateBusIn of the

LS_DigitalInput

system block, the current status of the

state bus can be queried. In case of error the output DIGIN_bStateBusIn is set to TRUE.

8.6.2

Setting the state bus to the "Error" state

If the input DIGOUT_bStateBusOut of the

LS_DigitalOutput

system block is set to TRUE, the state

bus is set to "Error" and all connected nodes start their pre-programmed response.

LS_DigitalInput

DIGIN_bStateBusIn

CONTROL

GE

24E

SB

X2

LS_DigitalOutput

DIGOUT_bStateBusOut

GE

24E

SB

X2

CONTROL