1 telegram structure, 2 parameter setting, 9"can on board" system bus – Lenze 9400 User Manual

Page 335

Advertising
background image

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

335

9

"CAN on board" system bus

9.9

Monitoring

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

9.9.2.1

Telegram structure

• The heartbeat telegram of the producer has the following identifier:

Identifier (COB-ID) = 1792 + producer's node address

• The user data (1 byte) contain the status (s) of the producer:

9.9.2.2

Parameter setting

Short overview of the parameters for the "Heartbeat" monitoring function:

Heartbeat producer time
Time interval for the transmission of the heartbeat telegram to the consumer(s).

• Parameterisable in

C00381

or via object

I-1017

. The parameterised time is rounded down to an

integer multiple of 5 ms.

• The heartbeat telegram is sent automatically as soon as a time > 0 ms is set.

Heartbeat producer status

Data

Communication status

Decimal value

(s)

(r)

Producer status (s)

Bit 7

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

Boot-up

0

0

0

0

0

0

0

0

0

Stopped

4

0

0

0

0

0

1

0

0

Operational

5

0

0

0

0

0

1

0

1

Pre-operational

127

0

1

1

1

1

1

1

1

Parameter

Info

Lenze setting

Assignment

Value Unit

Consumer

Producer

C00346

CAN heartbeat activity

-

C00347/1...32

CAN heartbeat status

-

C00381

CAN Heartbeat producer time

0 ms

C00385/1...32

CAN heartbeat consumer time

0x00000000

C00613/1...32

Resp. to CAN Heartbeat error

No response

C00625

CAN behaviour in case of fault

Pre-operational state

Greyed out = display parameter

Note!

Heartbeat and node guarding protocols must not be used simultaneously in a CANopen

device. If the heartbeat producer time is set > 0 ms, the heartbeat protocol is used.

Advertising
This manual is related to the following products: