5 profile data set change-over, Profile data set change-over, 11 basic drive functions – Lenze 9400 User Manual

Page 424

Advertising
background image

11

Basic drive functions

11.6

Homing

424

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

11.6.2.5

Profile data set change-over

For the reference search two profile data sets can be parameterised to reduce the homing time and

increase the accuracy:

• With the profile data set 1 first the limit switch/reference switch (depending on the mode

selected) is quickly approached.

• After reversing on the limit switch/reference switch, the slower – but more accurate – approach

of the encoder zero pulse/touch probe sensor and the positioning to the target position

(

C02643

) are effected with profile data set 2.

Profile data set 1

Profile data set 2

C02644

Speed 1

C02646

Speed 2

C02645

Acceleration 1

(and deceleration 1)

C02647

Acceleration 2

(and deceleration 2)

C02648

S-ramp time

(identical in the two profile data sets)

Setting the S-ramp time ( 382)

C02648

S-ramp time

(identical in the two profile data sets)

Setting the S-ramp time ( 382)

Note!

The change-over to profile data set 2 is only effected if speed 2 (

C02646

) is set > "0"!

In the Lenze setting (

C02646

= "0") no change-over to the profile data set 2 takes place

and the reference search and positioning to the target position is only executed with the

profile parameters of the profile data set 1.
The process descriptions of the homing modes provide information about when the

change-over to profile data set 2 takes place in the respective homing mode.

Overview

of the Lenze homing modes

( 427)

Advertising