Mode 0: pos. direction - via home mark - to tp, 11 basic drive functions – Lenze 9400 User Manual

Page 428

Advertising
background image

11

Basic drive functions

11.6

Homing

428

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Mode 0: pos. direction - via home mark - to TP

Procedure:

1. Movement in positive direction with profile data set 1.
2. Positive edge at HM_bHomingMark activates profile data set 2 for the further reference search.
3. Negative edge at HM_bHomingMark enables home position detection.
4. The following positive edge of the encoder zero pulse/touch probe sensor sets the reference.
5. Absolute positioning to target position (

C02643

) with profile data set 2 (if

C02641

= "0").

Note!

Drive behaviour after setting the reference

From software version V4.0 onwards

,

C02641

serves to parameterise the drive

behaviour after setting the home position.

Drive behaviour after setting the home position

( 423)

In the Lenze setting (

C02641

= "0"), the drive traverses to the absolute target position set

in

C02643

similarly to the behaviour known from the previous versions.

 Touch probe/zero pulse

 Reference switch

1

0