_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Mode 10: pos. direction - reversing to limit switch - to TP

Procedure:

1. Movement in positive direction with profile data set 1.
2. Reversing when the edge of the positive travel range limit switch is positive and, at the same

time, activation of profile data set 2 for continued reference searching.

3. The touch probe signal is evaluated while reserving the limit switch.
4. The following positive edge of the touch probe sensor sets the reference.
5. Absolute positioning to target position (

C02643

) with profile data set 2 (if

C02641

= "0").

 Touch probe/zero pulse

 Positive travel range limit switch

Note!

The touch probe detection is already activated after reversing to the travel range limit

switch, i.e. the home position may be set to the travel range limit switch.

• We therefore recommend to set a target position (

C02643

) unequal to the home

position (

C02642

), in order to reenable the activated limit switch. Otherwise, the

positioning process to the target position may be aborted by the basic function

"

Limiter

" (see status signal HM_dnState).

• We recommend the use of the DS402 homing methods 1 and 2 if the touch probe

detection (especially the one of the motor zero pulse) is to be activated after the travel

range switch has been left.

Overview of DS402 homing modes