2 parameter setting, Parameter setting, 11 basic drive functions – Lenze 9400 User Manual

Page 507

Advertising
background image

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

507

11

Basic drive functions

11.11

Limiter

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

11.11.2

Parameter setting

• Parameterisation dialog in »Engineer«: Tab Application parameters  Dialog level Overview

All basic functions Limiter

• Short overview of the parameters for the limiter:

Parameter

Info

C02700

Software limits pos. effective

C02701/1

Positive software limit position

C02701/2

Negative software limit position

C02702

Limitations effective

C02703

Max. speed

C02704

Max. speed [rpm]

C02705

Max. acceleration

C02706

Min. S-ramp time

C02707

Permissible direction of rotation

C02708/1...4

Limited speed 1 .... 4

C02709/1...4

Limited speed 1 .... 4 (display in [rpm])

C02710/1...4

Dec. limited speed 1 .... 4

C02711/1...4

S-ramp time limited speed 1 .... 4

C02712/1...4

Dec. time limited speed 1 .... 4

C02713

Max. manual jog distance

C02714

Max. dist. manual control (display in [increments])

C02715

Limitation active (status display)

C02716/1

Resp. to rotation limitation

C02716/2

Resp. to SW lim. pos. exceeded

C02716/3

Resp. to max. value exceeded

C02720

Observation software limit positions

Greyed out = display parameter

Note!

The safety module has its own parameters.
Relevant to the basic function "Limiter" are the parameters of the safety modules for

setting "Limited direction of rotation", "Speed with time limit" and "Limited increment

(position)".
However, several other parameters of the safety module have no significance for the

basic function "Limiter", e. g. the parameters for the configuration of the inputs of the

safety module.

Advertising
This manual is related to the following products: