Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

571

11

Basic drive functions

11.14

Pole position identification

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

11.14.1

Internal interfaces | System block "LS_PolePositionIdentification"

The LS_PolePositionIdentification system block provides the internal interfaces for the basic

function "identification of pole position" in the function block editor.

Inputs

Note!

Ensure that the system block is called in a cyclic application task.
Basically, projects which only contain an unsolicited task and no cyclic task are not

permissible!

Identifier

DIS code | data type

Information/possible settings

PPI_bEnable

C02789/1

| BOOL

Requesting control via the basic function.

TRUE If no other basic function is active, a change-over to the

"Identification of pole position active" function state is effected and

an identification of pole position can be carried out via the control

inputs.

TRUEFALSE An active identification of pole position is stopped, i.e. a change-over

from the active "Identification of pole position active" function state

back to the "Controller not ready" basic state is effected.

PPI_bStart

C02789/2

| BOOL

Start pole position identification

FALSETRUE Pole position identification is started in the mode selected in

C02786

.

PPI_bLoadPolePosition

C02789/3

| BOOL

Start pole position identification

FALSETRUE The pole position angle applied at PPI_dnPolePosition is accepted in

C00058/x

.

• The subcode to be described of

C00058

depends on the motor

encoder selected in

C00495

.

PPI_dnPolePosition

C02788

| DINT

Pole position angle in [°] with one decimal position

• Value range: -179.9 ... +179.9 °

PPI_bResetPolePosition

C02789/4

| BOOL

Reset "Pole position known" status

FALSETRUE The status outputs PPI_bDone and PPI_bPolePositionAvailable are

reset to FALSE.

LS_PolePositionIdentification

PPI_bEnable

PPI_bLoadPolePosition

PPI_dnPolePosition

PPI_bResetPolePosition

PPI_bEnabled

PPI_bActive

PPI_bStart

PPI_dnState

PPI_bDone

PPI_bError

PPI_bPolePositionAvailable

S

N

N

S

N

S

S

N