Inside the device: fan is defective [0x00770011, Device utilisation ixt > c00123 [0x00780000, Device utilisation ixt > 100 % [0x00780001 – Lenze 9400 User Manual

Page 645: Motor load i·xt > c00127 [0x00780002, Motor load i·xt > c00120 [0x00780003, 0x00780001, 0x00780000, 0x00770011, 0x00780003, 0x00780002

Advertising
background image

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

645

13

Diagnostics & fault analysis

13.7

Error messages of the operating system

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Inside the device: Fan is defective [0x00770011]

Device utilisation Ixt > C00123 [0x00780000]

Device utilisation Ixt > 100 % [0x00780001]

Motor load I²xt > C00127 [0x00780002]

Motor load I²xt > C00120 [0x00780003]

Module ID (decimal)

Error ID (decimal)

119: Temperature monitoring

17

Response (Lenze setting printed in bold)

Setting:

C00611

( Adjustable response)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

Speed of internal fan is too low, e.g. due to dirt.

Check/clean fan.

Module ID (decimal)

Error ID (decimal)

120: Analog signal monitoring

0

Response (Lenze setting printed in bold)

Setting:

C00604

( Adjustable response)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

Frequent and too long acceleration processes with

overcurrent >

C00123

.

Check drive dimensioning.

Module ID (decimal)

Error ID (decimal)

120: Analog signal monitoring

1

Response (Lenze setting printed in bold)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

Frequent and too long acceleration processes with

overcurrent.

Check drive dimensioning.

Module ID (decimal)

Error ID (decimal)

120: Analog signal monitoring

2

Response (Lenze setting printed in bold)

Setting:

C00606

( Adjustable response)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

Motor is thermally overloaded, e.g. due to:

• impermissible continuous current

• frequent or too long acceleration processes

• Check drive dimensioning.

• Check setting in

C00127

.

Module ID (decimal)

Error ID (decimal)

120: Analog signal monitoring

3

Response (Lenze setting printed in bold)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

Motor is thermally overloaded, e.g. due to:

• impermissible continuous current

• frequent or too long acceleration processes

• Check drive dimensioning.

• Check setting in

C00120

.

Advertising
This manual is related to the following products: