13

Diagnostics & fault analysis

13.7

Error messages of the operating system

650

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Motor: Calculated flux factor unrealistic [0x007b000d]

DC bus overvoltage [0x007b000e]

DC bus undervoltage [0x007b000f]

Overcurrent detected [0x007b0010]

Module ID (decimal)

Error ID (decimal)

123: Motor control

13

Response (Lenze setting printed in bold)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

Faulty motor parameterisation.

Check motor parameters.

Module ID (decimal)

Error ID (decimal)

123: Motor control

14

Response (Lenze setting printed in bold)

Setting:

C00600

( Adjustable response)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

Due to a too high braking energy, the DC-bus voltage

exceeds the overvoltage threshold which results from

the mains voltage setting in

C00173

.

• Use brake resistor or regenerative module.

• Check setting in

C00173

.

Module ID (decimal)

Error ID (decimal)

123: Motor control

15

Response (Lenze setting printed in bold)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

DC bus voltage is lower than the undervoltage threshold

resulting from the mains setting under

C00173

.

• Check mains voltage.

• Check setting in

C00173

.

Module ID (decimal)

Error ID (decimal)

123: Motor control

16

Response (Lenze setting printed in bold)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

• Short circuit/earth fault in motor cable.

• Excessive capacitive charging current in the motor

cable.

• Check motor cable.

• Use motor cable that is shorter or has a lower

capacitance.

Advertising
This manual is related to the following products: