Homing mode not allowed [0x00b80019, 0x00b80016, 0x00b80017 – Lenze 9400 User Manual

Page 703: 0x00b80019, 0x00b8001a, 13 diagnostics & fault analysis

Advertising
background image

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

703

13

Diagnostics & fault analysis

13.7

Error messages of the operating system

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Cam data locked due to incorrect password [0x00b80016]

Cam data locked due to incorrect safety key [0x00b80017]

Homing mode not allowed [0x00b80019]

Int. overflow C02620 (manual jog: Speed 1) [0x00b8001a]

Module ID (decimal)

Error ID (decimal)

184: Basic drive functions

22

Response (Lenze setting printed in bold)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

The cam data were locked since the user password was

entered incorrectly for three times.

The cam data were not loaded.

Reset parameters to the Lenze setting via device

command

C00002

= "0: Load Lenze setting". Then

download cam data again.

Module ID (decimal)

Error ID (decimal)

184: Basic drive functions

23

Response (Lenze setting printed in bold)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

The cam data were not loaded because the safety key is

damaged.

The password in the cam data or the serial number of the

memory module has been manipulated.

Reset parameters to the Lenze setting via device

command

C00002

= "0: Load Lenze setting". Then

download cam data again.

Module ID (decimal)

Error ID (decimal)

184: Basic drive functions

25

Response (Lenze setting printed in bold)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

From software version V3.0

The homing mode selected in

C02640

is not supported in

the motor control type selected in

C00006

.

Select another homing mode in

C02640

.

Module ID (decimal)

Error ID (decimal)

184: Basic drive functions

26

Response (Lenze setting printed in bold)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

From software version V3.0

Due to a subsequent change of the machine parameters

for gearbox ratio, feed constant, or resolution of an

encoder revolution, the value set in the parameter

cannot be displayed in the internal unit. See chapter

"

Max. position, speed, and acceleration that can be

displayed internally

".

• Check machine parameters and adapt them if

required.

• Change setting in

C02620

.

Advertising
This manual is related to the following products: