0x00b8001b, 0x00b8001c, 0x00b8001d – Lenze 9400 User Manual

Page 704: 13 diagnostics & fault analysis

Advertising
background image

13

Diagnostics & fault analysis

13.7

Error messages of the operating system

704

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Int. overflow C02621 (manual jog: Speed 2) [0x00b8001b]

Int. overflow C02622 (manual jog: Acceleration) [0x00b8001c]

Int. overflow C02623 (manual jog: Deceleration) [0x00b8001d]

Module ID (decimal)

Error ID (decimal)

184: Basic drive functions

27

Response (Lenze setting printed in bold)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

From software version V3.0

Due to a subsequent change of the machine parameters

for gearbox ratio, feed constant, or resolution of an

encoder revolution, the value set in the parameter

cannot be displayed in the internal unit. See chapter

"

Max. position, speed, and acceleration that can be

displayed internally

".

• Check machine parameters and adapt them if

required.

• Change setting in

C02621

.

Module ID (decimal)

Error ID (decimal)

184: Basic drive functions

28

Response (Lenze setting printed in bold)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

From software version V3.0

Due to a subsequent change of the machine parameters

for gearbox ratio, feed constant, or resolution of an

encoder revolution, the value set in the parameter

cannot be displayed in the internal unit. See chapter

"

Max. position, speed, and acceleration that can be

displayed internally

".

• Check machine parameters and adapt them if

required.

• Change setting in

C02622

.

Module ID (decimal)

Error ID (decimal)

184: Basic drive functions

29

Response (Lenze setting printed in bold)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

From software version V3.0

Due to a subsequent change of the machine parameters

for gearbox ratio, feed constant, or resolution of an

encoder revolution, the value set in the parameter

cannot be displayed in the internal unit. See chapter

"

Max. position, speed, and acceleration that can be

displayed internally

".

• Check machine parameters and adapt them if

required.

• Change setting in

C02623

.