Int. overflow c02703 (maximum speed) [0x00b80022, 0x00b80020, 0x00b80021 – Lenze 9400 User Manual

Page 705: 0x00b80022, 13 diagnostics & fault analysis

Advertising
background image

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

705

13

Diagnostics & fault analysis

13.7

Error messages of the operating system

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Int. overflow C02701/1 (positive software limit position) [0x00b80020]

Int. overflow C02701/2 (negative software limit position) [0x00b80021]

Int. overflow C02703 (maximum speed) [0x00b80022]

Module ID (decimal)

Error ID (decimal)

184: Basic drive functions

32

Response (Lenze setting printed in bold)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

From software version V3.0

Due to a subsequent change of the machine parameters

for gearbox ratio, feed constant, or resolution of an

encoder revolution, the value set in the parameter

cannot be displayed in the internal unit. See chapter

"

Max. position, speed, and acceleration that can be

displayed internally

".

• Check machine parameters and adapt them if

required.

• Change setting in

C02701/1

.

Module ID (decimal)

Error ID (decimal)

184: Basic drive functions

33

Response (Lenze setting printed in bold)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

From software version V3.0

Due to a subsequent change of the machine parameters

for gearbox ratio, feed constant, or resolution of an

encoder revolution, the value set in the parameter

cannot be displayed in the internal unit. See chapter

"

Max. position, speed, and acceleration that can be

displayed internally

".

• Check machine parameters and adapt them if

required.

• Change setting in

C02701/2

.

Module ID (decimal)

Error ID (decimal)

184: Basic drive functions

34

Response (Lenze setting printed in bold)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

From software version V3.0

Due to a subsequent change of the machine parameters

for gearbox ratio, feed constant, or resolution of an

encoder revolution, the value set in the parameter

cannot be displayed in the internal unit. See chapter

"

Max. position, speed, and acceleration that can be

displayed internally

".

• Check machine parameters and adapt them if

required.

• Change setting in

C02703

.