Int. overflow c02642 (home position) [0x00b8002d, 0x00b8002d, 0x00b8002e – Lenze 9400 User Manual

Page 709: 0x00b8002c, 13 diagnostics & fault analysis

Advertising
background image

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

709

13

Diagnostics & fault analysis

13.7

Error messages of the operating system

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Int. overflow C02713 (max. dist. manual control) [0x00b8002c]

Int. overflow C02642 (home position) [0x00b8002d]

Int. overflow C02643 (homing: Target position) [0x00b8002e]

Module ID (decimal)

Error ID (decimal)

184: Basic drive functions

44

Response (Lenze setting printed in bold)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

From software version V3.0

Due to a subsequent change of the machine parameters

for gearbox ratio, feed constant, or resolution of an

encoder revolution, the value set in the parameter

cannot be displayed in the internal unit. See chapter

"

Max. position, speed, and acceleration that can be

displayed internally

".

• Check machine parameters and adapt them if

required.

• Change setting in

C02713

.

Module ID (decimal)

Error ID (decimal)

184: Basic drive functions

45

Response (Lenze setting printed in bold)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

From software version V3.0

Due to a subsequent change of the machine parameters

for gearbox ratio, feed constant, or resolution of an

encoder revolution, the value set in the parameter

cannot be displayed in the internal unit. See chapter

"

Max. position, speed, and acceleration that can be

displayed internally

".

• Check machine parameters and adapt them if

required.

• Change setting in

C02642

.

Module ID (decimal)

Error ID (decimal)

184: Basic drive functions

46

Response (Lenze setting printed in bold)

None  System fault  Fault  Trouble  Quick stop by trouble  Warning locked  Warning  Information

Cause

Remedy

From software version V3.0

Due to a subsequent change of the machine parameters

for gearbox ratio, feed constant, or resolution of an

encoder revolution, the value set in the parameter

cannot be displayed in the internal unit. See chapter

"

Max. position, speed, and acceleration that can be

displayed internally

".

• Check machine parameters and adapt them if

required.

• Change setting in

C02643

.