27 calculate speed controller parameters, Calculate speed controller parameters, 4drive interface – Lenze 9400 User Manual

Page 74

Advertising
background image

4

Drive interface

4.2

Device commands

74

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

4.2.27

Calculate speed controller parameters

This function extension is available from software version V5.0 onwards!

The device command

C00002

= "78: Calculate speed controller parameters" is used to calculate the

gain, reset time, and rate time of the speed controller.
Precondition: The moments of inertia for the motor (

C00273/1

) and load (

C00273/2

) have been

parameterised correctly before.

• The calculation is carried out according to the following formulas, taking the actual speed value

filter time constant into consideration (

C00497

):

• After the device command has been executed successfully (see status in

C00003

), the calculated

values are set in the corresponding codes:

C00070

: Speed controller gain

C00071

: Speed controller reset time

C00072

: Speed controller rate time

• In the event of an error, these codes are not altered.

Possible status displays for this device command

Related device commands

Calculate current controller parameters

( 72)

Note!

The device command is no identification procedure for determining the speed controller

parameters!

Status (

C00003

)

Meaning

5145858 Device command in process

5111808 Device command executed successfully

5111809 General fault
5151540 At least one calculated value is outside the valid setting range.

Gain

Moment of inertia of motor+load

4 Actual speed value filter time constant 500 μs

+

(

)

----------------------------------------------------------------------------------------------------------------------------------------- 2π

60

------

=

Reset time

4

2

Actual speed value filter time constant 500 μs

+

(

)

=

Rate time

0 ms

=

Advertising