C00130 | rated power - brake resistor, C00131 - rated quantity of heat for brake res, C00133 | ref.: brake chopper utilisation – Lenze 9400 User Manual

Page 746: C00134 | minimum brake resistance, C00130, C00131, C00133, C00134, Ing in, C00173

Advertising
background image

14

Parameter reference

14.2

Parameter list | C00130

746

Lenze · Servo-Inverter 9400 HighLine · Reference manual · DMS 10.0 EN · 11/2013 · TD05/06

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00130

C00131

C00132

C00133

C00134

Parameter | Name:

C00130 | Rated power - brake resistor

Data type: INTEGER_32

Index: 24445

d

= 5F7D

h

Required for monitoring of the brake resistor temperature.

Braking operation

Setting range

(min. value | unit | max. value)

Lenze setting

0

W

800000 5600 W

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C00131 - Rated quantity of heat for brake res.

Data type: INTEGER_32

Index: 24444

d

= 5F7C

h

Required for monitoring of the brake resistor temperature.

Braking operation

Setting range

(min. value | unit | max. value)

Lenze setting

0

kWs

100000 485 kWs

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C00132 | Service code

Data type: INTEGER_32

Index: 24443

d

= 5F7B

h

This code is for device-internal use only and must not be written to by the user!

Parameter | Name:

C00133 | Ref.: Brake chopper utilisation

Data type: UNSIGNED_8

Index: 24442

d

= 5F7A

h

From software version V1.5

Braking operation

Selection list

(Lenze setting printed in bold)

Info

0 Minimum resistance (C00134)

C00134

1 Resistance in C00129

C00129

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 1

Parameter | Name:

C00134 | Minimum brake resistance

Data type: INTEGER_32

Index: 24441

d

= 5F79

h

From software version V1.5

Braking operation

Display range

(min. value | unit | max. value)

0.0

Ohm

500.0

Read access  Write access  CINH  PLC STOP  No transfer

Scaling factor: 10

Advertising