3.18 Results and more determination data

136

PC Control / Touch Control

determination are deleted and you return to the properties of the

determination.

3.18.5 Save determination

You can save the current determination on Card 1, Card 2 or a

shared file system (requires 847 USB Lab Link, see Section 3.10.11). In

this way you can store all the data of a determination. If you wish to

save every determination then you can use the function Save

automatically (see Section 3.16.10). Under Sequence/Method

options you can define that all the determination data is to be saved at

the end of each determination. If the data is saved automatically with

the standard settings then each determination will be automatically

write-protected. In this way your original data is protected and can

neither be edited nor deleted.

In the dialog Results/More determination data, open the

selection Load/Save.

Press Save. The procedure for saving a file is described in

Section 3.11.4. The file name Identification 1-YYYYMMDD-hhmmss

is proposed as default. This means that the file name consists of

the text entered as Identification 1 and the determination time. You

can also enter any other file name you choose. The extension of the

file name with the determination time has the advantage that the file

names of all determinations are unambiguous.

The following data is stored for each determination:
• Calculated results.
• All raw data (measuring point lists, endpoints...) and variables

produced during the determination.

• Determination properties.
• Statistics, if statistical calculations have been carried out.
• Method with which the determination was carried out.
• Common variables (values and properties of all common variables

at the time of the determination).

• Most important titrant data for the titrants used.
• Most important calibration data for the sensors used.

Note!

The data saved with each determination ensures that the data is

traceable and that the documentation is GLP-conform.

3.18.6 Load determination data

You can load determination files from Card 1, Card 2 or a shared file

system (requires 847 USB Lab Link, see Section 3.10.11).

In the dialog Results/More determination data open the

selection Load/Save. Touch Control: If no card is inserted or no

external file system is shared, then the [Load] button is inactive.

Open the dialog Load and select [Card 1], [Card 2] or [Shared

memory] (if present).