3.24 Manual control

180

PC Control / Touch Control

For type 8XX dosing devices with an intelligent exchange unit or dosing

unit the data stored on the data chip will be displayed.
For type 6xx or 7xx dosing devices you can select a titrant from the

titrants configured under System/Titrants. Only those titrants which

are suitable for use with the corresponding type of dosing device will be

shown in the selection list, i.e. dosing units for Dosinos and exchange

units for Dosimats. The cylinder volume is checked when dosing is

carried out.

The details of the subdialogs are described on the following pages.

Dosing
Under manual control dosing will be carried out for as long as the

[Dose] button is pressed down.

Press [Dosing] to open the dialog for manual dosing.

Enter the Dosing rate. The rate should be reduced for viscous

liquids. The maximum dosing rate depends on the cylinder volume

of the exchange or dosing unit used (see Section 3.8.6). Dynamic

means that dosing will be carried out quicker and quicker until the

maximum dosing rate has been reached (starting with 1 mL/min

and then doubling the dosing rate every 1.5 s). Dynamic can only be

selected when the dosing cylinder is filled. If dynamic dosing is