This Qsys design example provides detailed step-by-step instructions to generate a Qsys system. When

you install the Quartus II software you also install the IP Library. This installation includes design

examples for the Avalon-MM Arria 10 Hard IP for PCI Express in the

<install_dir>/ip/altera/altera_pcie/

altera_pcie_a10_ed/example_design/a10

directory. This walkthrough uses a Gen2 x4 Endpoint,

ep_g2x4_avmm128.qsys.
The design examples contain the following components:
• Avalon-MM Arria 10 Hard IP for PCI Express IP core

• On-Chip memory

• DMA controller

Figure 2-1: Qsys Generated Endpoint

Transaction,

Data Link,

and PHY

Layers

O n-C hip

Memory

DMA

Qsys System Design for PCI Express

PCI Express

Link

PCI

Express

Avalon-MM

Bridge

In

ter

connec

t

Avalon-MM Hard IP for PCI Express

The design example transfers data between an on-chip memory buffer located on the Avalon-MM side

and a PCI Express memory buffer located on the root complex side. The data transfer uses the DMA

component which is programmed by the PCI Express software application running on the Root Complex

processor.

Related Information

Generating the Example Design

on page 2-3

©

2015 Altera Corporation. All rights reserved. ALTERA, ARRIA, CYCLONE, ENPIRION, MAX, MEGACORE, NIOS, QUARTUS and STRATIX words and logos are

trademarks of Altera Corporation and registered in the U.S. Patent and Trademark Office and in other countries. All other words and logos identified as

trademarks or service marks are the property of their respective holders as described at

www.altera.com/common/legal.html

. Altera warrants performance

of its semiconductor products to current specifications in accordance with Altera's standard warranty, but reserves the right to make changes to any

products and services at any time without notice. Altera assumes no responsibility or liability arising out of the application or use of any information,

product, or service described herein except as expressly agreed to in writing by Altera. Altera customers are advised to obtain the latest version of device

specifications before relying on any published information and before placing orders for products or services.

ISO

9001:2008

Registered

www.altera.com

101 Innovation Drive, San Jose, CA 95134

Advertising