Finalizing processlogix client installation, Transferring r320.0 data to the r500.1 client, Remap the t: drive – Rockwell Automation 1757-SWKIT5000 ProcessLogix R500.1 Installation and Upgrade Guide User Manual
Page 144: Transfer r320.0 data, Finalizing processlogix client installation -20, Transferring r320.0 data to the r500.1 client -20, Remap the t: drive -20 transfer r320.0 data -20

Publication 1757-IN500A-EN-P - September 2002
5-20 ProcessLogix Client Installation and Upgrade Procedures
Finalizing ProcessLogix
Client Installation
Transferring R320.0 Data to the R500.1 Client
1. Logon to the R500.1 Client as ps_user.
2. Open Windows Explorer and confirm that the T: drive exists.
• If the T: drive exists, skip to Transfer R320.0 Data on page 5-20.
• If the T: drive does not exist, continue with Remap the T: Drive on
Remap the T: Drive
3. Click Start
⇒
Run.
4. Enter this command:
>cmd<
and click OK to open the DOS window.
5. Enter this command:
>NET USE T: \\STN01\C$ /user:ps_user<
(where STN01 is the remote PC name and ps_user is the user currently
logged on to STN01.)
and press <Enter>.
Transfer R320.0 Data
6. Click Start
⇒
Run.
7. Enter this command:
>cmd<
and click OK to open the DOS window.