Rockwell Automation SP600 AC Drive User Manual Version 1.0 User Manual
Page 120
![background image](/manuals/580999/120/background.png)
10-4
SP600 AC Drive User Manual
Speed Limits
• Minimum, Maximum
• Direction Limit
• Stop Mode
Reference Setup
• OIM, Terminal Block, Network, Other
Configure I/O
• Digital Inputs/Outputs
• Two-/Three-Wire Start
• Analog Outputs
As you adjust the parameters in the Start-Up routines, record them
in Appendix E.
When you have completed adjusting all of the parameters in the
Start-Up routines that your application requires, select the last item
in the menu, Done.
Exiting Before Completing the Start-Up Routines
To exit the Start-Up routines, press the F4 key (Exit). When you
select the Start-Up icon from the main menu again, you will be
prompted to either continue or restart the Start-Up routines. If you
select “continue,” you will be returned to the point at which you
exited.
!
ATTENTION: Rotation of the motor in an undesired
direction can occur during the Autotune procedure
(Autotune (61) = Rotate Tune). Disconnect the motor
before proceeding. Failure to observe this
precaution can result in damage to, or destruction
of, the equipment.