Parameter Descriptions
12-73
Displays the output state of the logic function control block resulting
from the combination of all port requests and masking functions.
Each bit or set of bits represent a command to the drive. Bit 6 will
always = 0.
Displays the present frequency reference scaled as a DPI reference
for peer-to-peer communications. The value shown is the output
prior to the accel/decel ramp and any corrections supplied by slip
comp, PI, etc.
271
Drive Logic Rslt
Range:
See figure12.43
Default:
Read Only
Access:
2
Path: Communication>Comm Control
See also:
Figure 12.43 – Drive Logic Rslt (271)
0
1
1
0
0
0
0
1
0
1
1
1
0
0
0
0
10
0
1
2
3
4
5
6
7
8
9
11
12
13
14
15
1 =Condition Active
0 =Condition Inactive
x =Reserved
Bit #
Stop
Star
t
Jog
Clear F
ault
Forw
ard
Re
verse
Local Contr
l
Mop Inc
Accel 1
Accel 2
Decel 1
Decel 2
Spd Ref ID 0
(1)
Spd Ref ID 1
(1)
Spd Ref ID 2
(1)
MOP Dec
Nibble 1
Nibble 2
Nibble 3
Nibble 4
Bits
(1)
Description
14
13
12
0
0
0
0
1
1
1
1
0
0
1
1
0
0
1
1
0
1
0
1
0
1
0
1
No Command - Man. Mode
Ref A Auto
Preset 2 Auto
Preset 3 Auto
Preset 4 Auto
Preset 5 Auto
Preset 6 Auto
Preset 7 Auto
272
Drive Ref Rslt
Range:
0 to 32767 [1]
Default:
Read Only
Access:
2
Path: Communication>Comm Control
See also: