12-66
SP600 AC Drive User Manual
Displays the current state of the digital outputs.
Displays the present operating temperature of the drive power
section.
Displays the accumulated percentage of drive overload.
Continuously operating the drive over 100% of its rating will
increase the value of Drive OL Count to 100% and cause a drive
fault or foldback depending on the setting of Drive OL Mode (150).
217
Dig Out Status
Range:
See figure12.36
Default:
Read Only
Access:
2
Path: Utility>Diagnostics
Inputs & Outputs>Digital Outputs
See also:
380-384
Figure 12.36 – Dig Out Status (217)
0
x
x
0
x
x
x
x
x
x
x
x
x
x
x
x
10
0
1
2
3
4
5
6
7
8
9
11
12
13
14
15
1 =Output Energized
0 =Output De-energized
x =Reserved
Bit #
Digital Out1
Digital Out2
Nibble 1
Nibble 2
Nibble 3
Nibble 4
Function
Terminal
Digital Out1
Relay 1, NO, 11/12
Relay 1, NC, 12/13
Digital Out2
Relay 2, NO, 24/25
Relay 2, NC, 25/26
218
Drive Temp
Range:
-/+100 degC [0.1 degC]
Default:
Read Only
Access:
2
Path: Utility>Diagnostics
See also:
219
Drive OL Count
Range:
0.0 to 100.0% [0.1%]
Default:
Read Only
Access:
2
Path: Utility>Diagnostics
See also:
150