Rockwell Automation SP600 AC Drive User Manual Version 1.0 User Manual

Page 191

Advertising
background image

Parameter Descriptions

12-61

Displays the present operating status of the drive.

209

Drive Status 1

Range:

See figure12.30

Default:

Read Only

Access:

2

Path: Utility>Diagnostics

See also:

210

Figure 12.30 – Drive Status 1 (209)

0

1

1

0

0

0

0

1

0

1

1

1

0

0

0

0

10

0

1

2

3

4

5

6

7

8

9

11

12

13

14

15

1 =Condition True
0 =Condition False
x =Reserved

Bit #

Ready

Active

Command Dir

Actual Dir

Accelerating

Decelerating

Alarm

Faulted

At Speed

Local ID 0

(1)

Local ID 1

(1)

Local ID 2

(1)

Spd Ref ID 0

(2)

Spd Ref ID 1

(2)

Spd Ref ID 2

(2)

Spd Ref ID 3

(2)

Nibble 1

Nibble 2

Nibble 3

Nibble 4

Bits

(2)

Description

Bits

(1)

Description

15 14 13 12

11 10 9

0
0
0
0
0
0
0
0
1
1
1
1
1
1
1

0
0
0
0
1
1
1
1
0
0
0
0
1
1
1

0
0
1
1
0
0
1
1
0
0
1
1
0
0
1

0
1
0
1
0
1
0
1
0
1
0
1
0
1
0

Ref A Auto
Preset 1 Auto
Preset 2 Auto
Preset 3 Auto
Preset 4 Auto
Preset 5 Auto
Preset 6 Auto
Preset 7 Auto
TB Manual
Port 1 Manual
Port 2 Manual
Port 3 Manual
Port 4 Manual
Port 5 Manual
Port 6 Manual

0
0
0
0
1
1
1
1

0
0
1
1
0
0
1
1

0
1
0
1
0
1
0
1

Port 0 (TB)
Port 1
Port 2
Port 3
Port 4
Port 5
Port 6
No Local Control

Bit

Function

Description

8

At Speed

Output frequency equal setpoint frequency.

7

Faulted

Drive fault active.

6

Alarm

Drive alarm active.

5

Decelerating

Drive decelerating.

4

Accelerating

Drive accelerating.

3

Actual Dir

Operating motor direction

2

Commanded Dir

Direction selected by the user.

1

Active

Drive is outputting voltage.

0

Ready

Drive is ready; no faults or inhibits, waiting
for valid start.

Advertising