Table 7.3 – Parameter Configuration for Figure 7.1 Wiring Example
Param.
Number
Description
Value
Default
89
Logic Source Sel
Terminal Block
Local OIM
90
Spd Ref A
Anlg #1
Local OIM
91
Spd Ref A Hi
60 Hz
Same as Max Speed
92
Spd Ref A Lo
0 Hz
0.0 Hz
96
TB Man Ref
Anlg #2
Anlg #2
97
TB Man Ref Hi
60 Hz
Same as Max Speed
98
TB Man Ref Lo
0 Hz
0.0 Hz
320
Analog Conf
xxx.xx01
xxx.xx01
322
Anlg In 1 Hi
20 mA
20 mA
323
Anlg In 1 Lo
4 mA
4 mA
325
Anlg In 2 Hi
10 V
10 V
326
Anlg In 2 Lo
0 V
0 V
361
Dig In 1 Sel
Stop
Stop
362
Dig In 2 Sel
Start
Start
363
Dig In 3 Sel
Function Loss
Function Loss
364
Dig In 4 Sel
Jog
Jog
365
Dig In 5 Sel
Manual
Manual
366
Dig In 6 Sel
Speed Sel 1
Speed Sel 1