Rockwell Automation SP600 AC Drive User Manual Version 1.0 User Manual

Page 85

Advertising
background image

Installing Control Wiring

7-3

Table 7.1 – Wiring Signal and Control I/O to the Terminal Block

No.

Signal

Factory

Default

Description

Re

la

te

d

Pa

ra

m

.

1

Digital In1 Sel

Stop – CF

(CF = Clear
Fault)

11.2 mA @ 24V DC
19.2V minimum on state
3.2V maximum off state
Important: Use only 24V DC, not
suitable for 115V AC circuitry.
Inputs can be wired as sink or source.

361 -
366

2

Digital In2 Sel

Start

3

Digital In3 Sel

Auto/Man

4

Digital In4 Sel

Speed Sel 1

5

Digital In5 Sel

Speed Sel 2

6

Digital In6 Sel

Speed Sel 3

7

24V Common

Drive supplied power for Digital In1-6
inputs.
150mA maximum load.

8

Digital In Common

9

+24V DC

10

+10V Pot Reference

2 k ohm minimum load.

11

Digital Out 1 – N.O.

1

NOT Fault

Max Resistive
Load
250 VAC/30 VDC
50 VAC / 60 Watts

Minimum DC
Load
10 µA, 10 mV DC

Max Inductive
Load
250 VAC/30 DC
25 VAC / 30 Watts

380 -
387

12

Digital Out 1 Common

1

13

Digital Out 1 - N.C.

Fault

14

Analog In 1 (– Volts)

(2)

Voltage –
Reads value
at 14 & 15

Non-isolated, 0 to +10V, 10 bit,
100k ohm input impedance.

3

320 -
327

15

Analog In 1 (+ Volts)

16

Analog In 1 (– Current)

Non-isolated, 4-20mA, 10 bit,
100 ohm input impedance.

3

17

Analog In 1 (+ Current)

18

Analog In 2 (– Volts)

(2)

Voltage –
Reads value
at 18 & 19

Isolated, bipolar, differential, 0 to
+10V unipolar (10 bit) or ±10V bipolar
(10 bit & sign), 100k ohm input
impedance.

4

19

Analog In 2 (+ Volts)

20

Analog In 2 (– Current)

Isolated, 4-20mA, 10 bit & sign,
100 ohm input impedance.

(4)

21

Analog In 2 (+ Current)

22

Analog Out (– Volts)
10V Pot Common

(2)

Output Freq

0 to +10V, 10 bit, 10k ohm (2k ohm
minimum) load.
Referenced to chassis ground.
Common if internal 10V supply
(terminal 10) is used.

341 -
344

23

Analog Out (+ Volts)

14

26

13

1

Advertising