Technical Specifications

A-3

Important:

Removing the adhesive label from the drive changes
the NEMA enclosure rating from Type 1 Enclosed to
Open Type.

Table A.3 – Environment

Altitude

1000 m (3300 ft) max. without derating

Ambient Operating Temperature
Without Derating:
Open Type, IP20, IP54, NEMA

Type 1, and Flange Mount:

IP66 and NEMA Type 4X/12:

0 to 50°C (32 to 122°F)
0 to 40°C (32 to 104°F)

Storage Temperature (all const.) –40 to 70

°

C (158

°

F)

Atmosphere

Important:

Drive must not be installed
in an area where the
ambient atmosphere
contains volatile or
corrosive gas, vapors, or
dust. If the drive is not
going to be installed for a
period of time, it must be
stored in an area where it
will not be exposed to a
corrosive atmosphere.

Relative Humidity

5 to 95% non-condensing

Shock

15G peak for 11ms duration (

±1.0 ms)

Vibration

0.152 mm (0.006 in.) displacement, 1G
peak