Parameter Descriptions

12-29

Sets the amount of slip compensation to be added to the drive
output at 100% motor load. If parameter 61 (Autotune) = 3
(Calculate), changes made to this parameter will not be accepted.

Important:

Parameters in the Slip Comp Group (121-123) are
used to enable and tune the slip compensation
regulator. To allow the slip compensation regulator to
control drive operation, Speed Mode (80) must be set
to 1 (Slip Comp).

Sets the response time of slip compensation. Increasing the value
will increase the slip compensation response.

Important:

Parameters in the Slip Comp Group (121-123) are
used to enable and tune the slip compensation
regulator. To allow the slip compensation regulator to
control drive operation, Speed Mode (80) must be set
to 1 (Slip Comp).

Displays the present amount of slip adjustment being added to the
motor commanded frequency.

Important:

Parameters in the Slip Comp Group (121-123) are
used to enable and tune the slip compensation
regulator. To allow the slip compensation regulator to
control drive operation, Speed Mode (80) must be set
to 1 (Slip Comp).

121

Slip RPM @ FLA

Range:

0.0 to 1200.0 RPM

Default:

Based on Motor NP RPM

Access:

2

Path: Speed Command>Slip Comp

See also:

61, 80, 122, 123

122

Slip Comp Gain

Range:

1.0 to 100.0 [0.1]

Default:

40.0

Access:

2

Path: Speed Command>Slip Comp

See also:

80, 121, 122

123

Slip RPM Meter

Range:

0.0 to 300.0 RPM

Default:

Read Only

Access:

2

Path: Speed Command>Slip Comp

See also:

80, 121, 122